Connect delivery unit
WARNING:
Working on fuel system.
Risk of fire! Danger of explosion!
Risk of fire! Danger of explosion!
- When working on the fuel system, make sure the workstation has sufficient ventilation, e.g., by means of extraction.
- Tightly seal off open lines and connections; collect any leakage fuel directly at the point of exit.
- No fire, sparks, open flames or smoking.
NOTE:
TECHNICAL INFORMATION
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
- Position snap fastener (1) and lock.
- Connect connectors (2) and lock.
- Check that the fuel lines are properly locked by pulling.
It must be ensured that the fuel lines are properly locked.
- Replace the seal (1).
Parts: Gasket
- Mount the cover (2).
The arrow must point in the direction of travel.
- Replace plastic nuts (1).
Parts: Plastic nuts
- Insert plastic nuts (1) and tighten.
TIGHTENING TORQUES SPECIFICATION
| Cover of sensor opening on body | |
| Replace plastic nut. | tightening torque 3 Nm |
- Close the floor trims in the area (1) in arrow direction.