Partially installing the left Lambda oxygen sensor
WARNING:
Hot surfaces.
Risk of burning!
Risk of burning!
- Perform all work only on components that have cooled down.
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: 61 35... NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION .
- Tighten the left Lambda oxygen sensor (1) with the special tool.TIGHTENING TORQUES SPECIFICATION
Front Lambda oxygen sensor/oxygen sensor monitor on catalytic converter M18x1.5 tightening torque
50 Nm - Secure the left Lambda oxygen sensor cable in area (2) in the cable bracket.