Install the coolant return line for the exhaust turbocharger
NOTE:
TECHNICAL INFORMATION
Make sure that the connections are locked correctly. The locks must engage audibly.
Make sure that the connections are locked correctly. The locks must engage audibly.
- Replace O-rings (1) on coolant return line (2) with special tool 0 496 714 (00 9 030)
.
Parts: O-rings
- Replace O-ring (1) on coolant feed line (2) with special tool 0 496 714 (00 9 030)
.
Parts: O-ring
- Insert and position the coolant return line (1) for the exhaust turbocharger.
- Connect the coolant return line (1) for the exhaust turbocharger and lock.
- Make sure that the coolant return line (1) for the exhaust turbocharger engages audibly.
- Insert and install the coolant return line (4) for the exhaust turbocharger.
- Insert and install the coolant feed line (2) for the exhaust turbocharger.
- Tighten down screw (1).TIGHTENING TORQUES SPECIFICATION
Coolant feed line/coolant return line to exhaust turbocharger M6 x 12 Tightening torque
8 Nm - Tighten down screw (3).
TIGHTENING TORQUES SPECIFICATION
| Coolant return line holder to exhaust turbocharger | |
| M6 | Tightening torque 8 Nm |