Home >> BMW >> 2017 >> 530i >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating And Air Conditioning - Repair (G30) (3 Of 3) >> 64 52 Compressor >> Instructions for opening and part exchange in refrigerant circuit (530i 2017-2022, 530i xDrive 2017-2022, 530e PHEV 2018-2022, 530e xDrive PHEV 2018-2022, 540i 2017-2022, 540i xDrive 2017-2022, M550i xDrive 2018-2022)

Instructions for opening and part exchange in refrigerant circuit (530i 2017-2022, 530i xDrive 2017-2022, 530e PHEV 2018-2022, 530e xDrive PHEV 2018-2022, 540i 2017-2022, 540i xDrive 2017-2022, M550i xDrive 2018-2022)

Required special tools: 

WARNING:

Attention! 

  1. Part replacement as preliminary work fur further repair work and part replacement based on gradual leakage. 

    (minor leak, e.g. hairline crack)

    Procedure: 

    • Draw off heating and air conditioning system, then determine drawn-off amount of refrigerant oil
    • Carry out part replacement
    • Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced: 
      • Compressor:  refer to NOTES  on compressor replacement
      • Evaporator:  10 mL
      • Capacitor:  20 mL
      • Desiccant insert/dryer flask  : 20 mL
      • Each replaced refrigerant line:  10 mL
      • Condenser with integrated dryer flask:  40 mL
      • Safety pressure switch and gasket:  no additional refrigerant oil
      • Only 101:  Radiator, high-voltage battery unit: 20 mL
    • Evacuate and fill air conditioning system
  2. II. Part replacement due to sudden leakage 

    (major leak, e.g. line disconnection due to accident)

    Procedure: 

    • Draw off heating and air conditioning system, then determine drawn-off amount of refrigerant oil
    • Carry out part replacement
    • Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced: 
      • Compressor:  refer to NOTES  on compressor replacement
      • Evaporator:  35 mL
      • Capacitor:  35 mL
      • Desiccant insert/dryer flask:  55 mL
      • Each replaced refrigerant line:  35 mL
      • Condenser with integrated dryer flask:  55 mL
      • Safety pressure switch and gasket:  no additional refrigerant oil
      • Only 101:  Radiator, high-voltage battery unit: 35 mL
    • EVACUATE and fill A/C system