NOTE:
TECHNICAL INFORMATION
Grease the threads of new oxygen sensors thinly and evenly.
For oxygen sensors that are reused, the following should be observed:
Thinly and evenly grease the oxygen sensor on the thread only. Do not clean the part of the oxygen sensor that does not protrude into the exhaust line (sensor ceramics) and do not grease.
For additional information see: OVERVIEW OF CONSUMABLES (BMW PARTS CATALOGUE) .
Grease the threads of new oxygen sensors thinly and evenly.
For oxygen sensors that are reused, the following should be observed:
Thinly and evenly grease the oxygen sensor on the thread only. Do not clean the part of the oxygen sensor that does not protrude into the exhaust line (sensor ceramics) and do not grease.
For additional information see: OVERVIEW OF CONSUMABLES (BMW PARTS CATALOGUE) .
- Prepare the oxygen sensor.
Do not damage the sensor ceramics.
- Thread
- Sensor ceramics
- Lightly and evenly grease the thread (1) of the oxygen sensor monitor.CONSUMABLE - BRAKE BLOCK PASTE DESCRIPTION
Brake block paste * TU = Trade Unit. TU numbers cannot be ordered! For invoicing purposes only. 3 g, Bag 83192158851 100 g, Tube 83192158852 5 g, TU* 83230140233 NOTE: The cable of the Lambda oxygen sensor is black. The installation location of the Lambda oxygen sensor is in front of the catalytic converter. - Screw in the Lambda oxygen sensor (1) and tighten with the special tool 0 491 074 (11 7 020)
.TIGHTENING TORQUES SPECIFICATION
Lambda oxygen sensor on catalytic converter M18X1.5 tightening torque 50 Nm - Feed in the heat protection (4) in direction of arrow and install.
- Replace the cable ties (3).
Parts: Cable tie
- Guide in cable tie (3) and install.
- Guide the line of the Lambda oxygen sensor (1) into the bracket (2) and install.
- Feed in the connector (1) in direction of the arrow and install.
- Ensure that the locking mechanism (2) engages audibly.
- Connect and lock the connector (1).
- Make sure the connector (1) engages audibly.
Follow-up work
- Refer to INSTALLING THE RESONATOR WITH THE TOP CLEAN AIR PIPE .
- Refer to INSTALLING INTAKE SILENCER HOUSING .
- Refer to INSTALLING ACOUSTIC COVER .