Erroneous Electric Fan Function Fault Stored In The DME (SI B12 16 19)
Publication date: 2020-04-30Reference number: SI B12 16 19
ERRONEOUS ELECTRIC FAN FUNCTION FAULT STORED IN THE DME
SERVICE CAMPAIGN BULLETIN
| BMW: | G01 (X3 Sports Activity Vehicle); G02 (X4 Sports Activity Vehicle); G12 (7 Series Sedan); G30 (5 Series Sedan); G32 (6 Series Gran Turismo) |
SERVICE INFORMATION
This Service Information Bulletin (Revision 1) replaces SI B12 16 19 dated May 2019.
What's New (Specific text highlighted):
- Correction
- Warranty Information was updated
Equipped with the B46O, B58M, or XB1H engine
MODEL
SITUATION
The following faults may be erroneously stored in the Digital Motor Electronics (DME):
| Fault code: | Control module: | Fault code text: |
|---|---|---|
| 1A2806 | DME | Electric fan, function: limited operation |
| 1A4007 | DME | Electric fan, function: Operating mode implausible |
And:
There is no customer-facing vehicle symptom(s) or related check control message displayed.
CAUSE
A software error may cause these faults to be erroneously stored in the Digital Motor Electronics (DME).
CORRECTION
The faults may only be considered erroneous if described as such in the following procedure.
In all other circumstances and conditions , the faults should be regarded as real faults and diagnosed with ISTA as needed.
PROCEDURE
Read out the environmental conditions and time stamps for 1A4007 and 1A2806.
If both faults were stored simultaneously or 1A4007 was stored up to 15 seconds after fault 1A2806 and the fault counter for each fault is 1, perform the following:
- Delete the fault memory
- Cycle the terminal status (ignition off, wait 30 seconds, ignition on)
- Activate the electric fan with ISTA for one minute
Path for electric fan activation:
- Control unit functions
- Component activation
- General
- Electric fan activation
- Cycle the terminal status (ignition off, wait 30 seconds, ignition on)
- Activate the electric fan a second time for one minute
- If neither of the faults have returned, they should be regarded as an erroneous fault and should be ignored
WARRANTY INFORMATION
In conjunction with the ISTA diagnosis of un-related issue(s), covered under the terms of the BMW New Vehicle Limited Warranty for Passenger Cars and Light Trucks.
| Defect Code: | 1711119900 | Electric fan Fault code stored in diagnosis fault code memory (no warning lamp) | |
|---|---|---|---|
| Labor Operation | Description | Labor Allowance | |
| 61 00 006 | Work time to delete the fault memory and evaluate the specified fault codes as outlined in the PROCEDURE section | 4 FRU | |
Work time labor operation code 61 00 006 is not considered a Main labor operation; however since this is a standalone repair; it does require an individual punch time and an explanation on the repair order and in the claim comments section.
Other Repairs
If other eligible and covered work is performed as a result of performing the ISTA diagnostics and related test plans, claim this work with the applicable defect code and the labor operations (including diagnosis) that are listed in AIR.