Removing The Outer Section Of The A-Pillar
Further information is available.
- Mark and carry out the separating cut (1) as per dimension a. Thereby disconnect only the outer panel. Dimension a = 85 mm.NOTE: TECHNICAL INFORMATION
For additional information see: 41 00... Releasing bonded connections - Open the spot-welded adhesive joints in areas (1) to (4).
NOTE:
RISK OF DAMAGE
Damage to bonded connection.
Influence of heat that is too large leads to damage on bonded connections lying on the beading or below.
Damage to bonded connection.
Influence of heat that is too large leads to damage on bonded connections lying on the beading or below.
- Warm bonded connection only for a short time, maximum up to 120°C.
- In area (4), do not damage the spot-welded adhesive joints that are between the second and third panel.
- Open welded connections in area (1).
- Detach the outer section of the A-pillar from the cavity sealings (2).
- Mark and carry out the separating cut (1) as per dimension a. Thereby disconnect only the outer panel. Dimension a = 340 mm.
- Release welded connections in areas (2).
- Release the spot-welded adhesive joints in area (3).
- Release and remove the A-pillar outer part from the cavity sealing (4).