LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> BMW >> 2017 >> 530i >> Repair and Diagnosis (Single Page) >> Electrical >> Body Electrical >> General Electrical System - Repair (G30) (1 Of 3) >> 61 20 Battery >> 61 20 900 Disconnecting and connecting battery ground lead (530e PHEV 2018-2022, 530e xDrive PHEV 2018-2022) >> Disconnecting the negative battery cable of the system battery

Disconnecting the negative battery cable of the system battery

Prerequisite 

Ignition is switched off.

WARNING: Deactivate the 12-V electrical system.
Risk of short circuits! Risk of fire! 
  • Make sure that there is no battery charger  connected to the jump start terminal in the engine compartment.
  • For vehicles with additional electrical systems (48 V electrical system, high-voltage vehicle electrical system), this absolutely must be deactivated before  the vehicle battery is disconnected.
NOTE: RISK OF DAMAGE 
Damage to battery terminal, the safety battery terminal or the intelligent battery sensor (IBS). 
Damaged battery terminals can lead to malfunctions or vehicle electrical system faults. 
  • Detach battery terminal from battery pole. Do not pry off using a tool.
G12676230Courtesy of BMW OF NORTH AMERICA, INC.