Install the wiring harness section for the ignition and injectors
NOTE:
RISK OF DAMAGE
Improper routing of cables and wiring harnesses.
Trapped, crushed or damaged cables may cause short circuits and malfunctions.
Improper routing of cables and wiring harnesses.
Trapped, crushed or damaged cables may cause short circuits and malfunctions.
- Route all cables without abrasions, do not trap and crush.
- Guide in and Install the wiring harness section for the ignition and injectors (4).
- Connect and lock the holder (3).
- Connect and lock the holder (2).
- Secure the clamp (1).
The holder (3) and clamps (1) must be heard to engage.
- Connect and lock the connector (1) to the injectors.
The connectors must engage audibly.
- Connect the connector to the injectors.
- Lock the locking mechanism (1) the arrow direction.
Lock must audibly engage.
- Thread in cable duct (3) and install.
- Thread in ground cable (2) and install.
- Tighten nut (1).
TIGHTENING TORQUES SPECIFICATION
| Ground cable to rail | ||
|---|---|---|
| M6 | tightening torque | 5 Nm |
- Connect and lock the connectors (arrows).
The connectors must engage audibly.
- Connect and lock all connectors (1) in the direction of the arrow.
The connectors must engage audibly.
- Slide the cover (1) in the direction of the arrow into the guide (2) and install it.
- Lock clamp (3).
The clamp must engage audibly.
Follow-up work
- Refer to INSTALLING ACOUSTIC COVER AT REAR .
- Refer to INSTALLING ACOUSTIC COVER .
- Refer to INSTALLING THE FRONT HOOD SEAL AT THE REAR .
- Refer to CONNECTING NEGATIVE BATTERY CABLE .
- Refer to ACTIVATING THE 48 V ELECTRICAL SYSTEM .