LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> BMW >> 2017 >> 530i >> Repair and Diagnosis (Single Page) >> Engine Mechanical >> Cooling System (Mechanical) >> Engine - Coolant Pump/Thermostat - Repair (G30) >> 11 53 Thermostat And Engine-Mounted Coolant Lines >> 11 53 015 Removing and installing/replacing heat management module (530e PHEV, 2021-2022, 530e xDrive PHEV, 2021-2022) >> Remove heat management module

Remove heat management module

WARNING: High-voltage system. 
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock! 
WARNING: Hot surfaces.
Risk of burning!
  • Perform all work only on components that have cooled down.
WARNING: Hot fluids.
Risk of scalding!
  • Conduct all work in the vehicle wearing appropriate personal protective equipment only.
WARNING: Working on 12 V electrical system.
Risk of short circuits! Risk of fire!
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
  • Detach battery ground lead from battery.
  • For auxiliary batteries: Detach battery minus cables from all auxiliary batteries.
NOTE: RISK OF DAMAGE 
Damage to battery terminal, the safety battery terminal or the intelligent battery sensor (IBS). 
Damaged battery terminals can lead to malfunctions or vehicle electrical system faults. 
  • Detach battery terminal from battery pole by carefully shifting to and fro. Do not pry off using a tool.
NOTE: TECHNICAL INFORMATION 
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.

Preliminary work 

Further information is available.

Heat management module 

G14216555Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: RISK OF DAMAGE 
Electrostatic discharge. 
Damage to or destruction of electrical components. 
  • Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
  • Read and comply with user information on using the associated special tool 12 7 060.
  • Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
  • Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
  • For additional information see: NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION
NOTE: RISK OF DAMAGE 
Damage to wires when disconnecting connectors and plug connections. 
Sheared wires can cause a short circuit. 
  • Do not pull on wires when disconnecting connectors and plug connections.
NOTE: TECHNICAL INFORMATION 
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.