Removing fuel delivery line
NOTE:
DANGER
High-voltage system.
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
High-voltage system.
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
- All work on the high-voltage system may only be carried out by specially trained and technically experienced personnel.
- For additional information see:
- For additional information see:
Preliminary work
- Refer to REMOVING THE ACOUSTIC COVER .
- Refer to DISCONNECTING ALL BATTERY GROUND LEADS .
- Refer to REMOVE THE SEAL FOR THE HOOD REAR .
- Refer to REMOVING ACOUSTIC COVER AT REAR
- Refer to REMOVE ALL IGNITION COILS .
WARNING:
Working on fuel system.
Risk of fire! Danger of explosion!
Risk of fire! Danger of explosion!
- When working on the fuel system, make sure the workstation has sufficient ventilation, e.g., by means of extraction.
- Tightly seal off open lines and connections; collect any leakage fuel directly at the point of exit.
- No fire, sparks, open flames or smoking.
CAUTION:
On releasing high pressure line, fuel may emerge at high speed.
Injury hazard!
Injury hazard!
- Wear suitable personal protective equipment.
- Before performing any installation work, allow cooling system to cool down to less than 40°C.
- Note warnings on cylinder head cover.
NOTE:
RISK OF DAMAGE
Contaminant or foreign body.
Contamination can result in malfunctions, loss of function or leaks.
Contaminant or foreign body.
Contamination can result in malfunctions, loss of function or leaks.
- Adhere to the utmost cleanliness.
- Protect components from contamination e.g. by covering.
- Close off line connections with seal plugs.
NOTE:
TECHNICAL INFORMATION
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
- Loosen clamp (1).
- Feed out the wiring harness section (2) for injectors and ignition coils and set aside.
- Unlock the locks (arrows).
- Feed out the wiring harness section (1) for injectors and ignition coils and set aside.
- Unlock and loosen lock (1).
- Feed out the tank vent line (2) from the clamp (3) and set aside.
- Unlock and loosen clamp (1).
- Unlock and remove the snap fastener (2) in the direction of the arrow.
- Catch and dispose of leakage fuel.
- Seal the fuel lines with special tools 0 496 567 (13 5 161) and 0 496 568 (13 5 162) from the set of special tools 0 496 565 (13 5 160) .
- Loosen screw (3).
- Slacken the union nut (1) on the high pressure pump.
- Catch and dispose of leakage fuel.
- Close all openings with the special tool 2 413 106 .
- Slide the fuel supply line (3) out and remove.
- Make sure the rubber damper (2) does not get lost.