Install charge air temperature sensor
NOTE:
RISK OF DAMAGE
Contaminant or foreign body.
Contamination can result in malfunctions, loss of function or leaks.
Contaminant or foreign body.
Contamination can result in malfunctions, loss of function or leaks.
- Adhere to the utmost cleanliness.
- Protect components from contamination e.g. by covering.
- Close off line connections with seal plugs.
- Check the sealing rings (1) on the charge-air temperature sensor for damage, replace if applicable.
- Insert and install the charge air temperature sensor. (2).
- Tighten the charge-air temperature sensor (2) using the special tool 0 496 142 (11 8 850)
.TIGHTENING TORQUES SPECIFICATION
Charge air temperature sensor on charge air line Sensor Tightening torque 1.8 Nm - Connect connectors (1) and lock.
The connector (1) must engage audibly.
Follow-up work
- Refer to INSTALLING ACOUSTIC COVER .