Replacing oil sump: remount the oil-level sensor
Additional information is available.
NOTE:
RISK OF DAMAGE
Electrostatic discharge.
Damage to or destruction of electrical components.
Electrostatic discharge.
Damage to or destruction of electrical components.
- Leave electrical components in original packaging until just before they are installed. Use the original packaging only for any return shipments. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only touch the housings of electrical components. Do not touch pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: NOTES ON ESD (ELECTROSTATIC DISCHARGE) PROTECTION
- Guide the seal plug (1) out of the oil sump (2) in the direction of arrow
and remove.
- Loosen nuts (1).
- Feed out and remove the oil-level sensor (2),
- Replace O-ring (1).
Parts: O-ring
- Insert and install the oil-level sensor (2).
- Tighten nuts (1).
TIGHTENING TORQUES SPECIFICATION
| Oil-level sensor to oil sump | ||
| M6 | Jointing torque | 2.5 Nm |
| Tightening torque | 8.5 Nm | |