Adjusting the electric wastegate valve adjuster (after vehicle diagnosis)
- Perform the following work steps only when the setting for the electric wastegate valve adjuster is specified by the vehicle diagnosis.
- Connect diagnostic system:
- Service functions
- Drive
- Engine electrical system
- Adjustment programs
- Adjusting wastegate linkage
NOTE:
TECHNICAL INFORMATION
The adjustment nuts must be locked using 2 open-end wrenches. If only one open-end wrench is used, there is a risk of the electrical controller drive being damaged.
The adjustment nuts must be locked using 2 open-end wrenches. If only one open-end wrench is used, there is a risk of the electrical controller drive being damaged.
- Mark the lock nut (1) and the adjustment nut (2) with a colored mark.
- Loosen lock nut (1).
- According to the diagnostic function: Shorten the adjustment travel (-) or extend the adjustment travel (+).
One rotation of the adjustment nut = 0.75 mm adjustment travel.
- Example 1:
- Measured actual value (via diagnostic function) = 0.75 mm
- Required correction: + 0.75 mm divided by 0.75 mm = + 1.0 rotations
For the correction of the setting of the control rod: Adjust lock nut (1) toward (+) by 1.0 rotations. Then reset the adjusting nut (2).
TIGHTENING TORQUES SPECIFICATIONControl rod for electric wastegate valve controller M6
Always use a second open-end wrench (for counter support) to tighten the lock nut!Tightening torque 6 ± 0.3 Nm - Example 2:
- Measured actual value (via diagnostic function) = - 1.5 mm
- Required correction: - 1.5 mm divided by 0.75 mm = 2.0 rotations
For the correction of the setting of the control rod: Adjust adjustment nut (2) toward (-) by 2.0 rotations. Then reset the lock nut (1).
TIGHTENING TORQUES SPECIFICATIONControl rod for electric wastegate valve controller M6
Always use a second open-end wrench (for counter support) to tighten the lock nut!Tightening torque 6 ± 0.3 Nm - After setting: Recheck the basic setting with the diagnostic function.
Follow-up work
- Refer to INSTALLING CLEAN AIR PIPE .
- Refer to INSTALLING RESONATOR .
- Refer to INSTALLING ACOUSTIC COVER .