Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis (Single Page) >> Electrical >> Starter >> Charging System (Battery, Starter And Generator) & Cruise Control (2 Of 2) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger :VAS5900 >> Battery Charger :VAS5900 SERVICE CHARGE >> Notes

Battery Charger :VAS5900 SERVICE CHARGE: Notes

Special Tools And Workshop Equipment Required 

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

CAUTION:

"Service charging" is not permitted for VW vehicles, because voltage surges can damage the on-board electronics.

The Battery -A- must always be disconnected from the vehicle electrical system when using the "service charge" mode.

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

CAUTION:

Always set the mode that corresponds to the Battery -A- during the charging process. Refer to the :VAS5900  Operating Instructions.

"Service Charging" is suitable for:

  • Wet batteries having a visual indicator which allows charging (visual indicator black or green).

The "Service charge (SERV)" mode is only used with sulfated Batteries -A-. The Battery -A- with voltages greater than 14.4 V is charged. A partial removal of the sulfation layer can result from this. Check the visual indicator after charging, immediately before the Battery -A- is used. Refer to VISUAL INDICATOR COLOR DISPLAY, CHECKING .

NOTE:

The Battery -A- temperature must be at least 10 °C (50 °F).