Evaporative Emissions Tester:KLI9210, Self-Test
Always perform system self-test of Evaporative Emissions Tester :KLI9210 prior to use to ensure that there are no leaks.
Refer to Evaporative Emissions Tester :KLI9210 instruction manual for specific instructions.
-- Connect vehicle interface hose to self-test port -1-, ensuring that fitting is finger-tight. Over-tightening will damage fitting.
-- Turn control valve -2- to Test.
Gauge -3- should read 14 ± 1 in. of water.
If gauge does not read 14 ± 1 in. of water:
-- Verify that valve on EVAP tester nitrogen cylinder is open and that cylinder has sufficient pressure before continuing.
-- Turn fine adjust regulator knob (-arrow-) until gauge reads 14 in. of water; tighten lock nut.
Courtesy of AUDI OF AMERICA, LLCIf gauge still does not read within above range, contact K-Line Customer Service - Technical Support for additional instructions before continuing.
-- Check flow meter -4-.
Meter must indicate no flow.
-- Turn control valve to Hold position.
-- Check gauge.
Gauge must hold pressure.
If gauge leaks down:
-- Verify that vehicle interface hose is firmly seated and repeat previous six steps before continuing.
If gauge continues to leak down:
-- Use ultrasonic tester to locate and repair leak before continuing. Refer to METHOD 2: LOCATE LEAK WITH ULTRASONIC TESTER
If the leak cannot be located or repaired, contact K-Line Customer Service - Technical Support.