Possible Deviation From Specified Value During The Pressure Test (10 Of 11)
| Possible Deviation from Specified Value during the Pressure Test |
|---|
|
| Possible causes for the deviation from specified value and their solutions |
|
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to ELECTRICALLY-DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
For cooling the Electric Vehicle Battery -A2- (hybrid battery) the refrigerant shut-off valve 1 is currently activated from a specific battery temperature for example from the battery regulation control module. If the A/C system driver is not already activated at this time, the Electrical A/C Compressor -V470- is activated via the A/C Compressor Control Module -J842- for example by the battery regulation control module. The temperature of the air (or the coolant) before and after the evaporator for battery cooling module is calculated by the respective control module (for example by the battery regulation control module). If at the same time it is determined that the cooling is not sufficient this is stored for example in the battery regulation control module. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding" function of the A/C system and the battery regulation.
The temperature of the air (or the coolant) and the evaporator cooling output in the battery cooling module is determined via the installed temperature sensor (it currently cannot be measured using a thermometer while operating) and may only for this reason be checked using the Guided Fault Finding. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding" function of the A/C System and the battery regulation.
Refer to Possible Deviation From Specified Value During The Pressure Test (1 Of 11) for further information.