Possible Deviation From Specified Value During The Pressure Test (5 Of 9)
| Possible Deviation from Specified Value during the Pressure Test |
|---|
|
| Possible causes for the deviation from specified value and their solutions |
|
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to MECHANICALLY DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
If there is too much refrigerant oil in the circuit, the A/C compressor must be emptied and the desiccant bag (the dryer cartridge) or the receiver/receiver/dryer must be replaced. After cleaning (flushing with refrigerant R1234yf) fill the refrigerant circuit with the correct quantity of refrigerant oil. Refer to REFRIGERANT CIRCUIT, CLEANING , APPROVED REFRIGERANT OILS AND REFRIGERANT OIL CAPACITIES and Refrigerant Circuit .
With this malfunction, evaporator may ice up although the quantity of refrigerant in circuit is OK.
Problem with Evaporator Vent Temperature Sensor -G263- can also cause icing-up of refrigerant circuit. For this concern also pay attention to the measured value of the Evaporator Vent Temperature Sensor -G263-. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding" function of the A/C system. Refer to Component Location Overview - A/C System .