Evaporator In Heater And A/C Unit, Cleaning With The Ultrasound A/C Cleaner
Special tools and workshop equipment required
- Ultrasound A/C Cleaner (for example the Ultrasound A/C Cleaner :VAS6189B ). Refer to the Parts Information for the cleaning device currently available.
- Ultrasound A/C Cleaner - Airco-Clean Fluid :VAS6189/1 . Refer to the Parts Information.
On a vehicle without an A/C system (only with a heater) the evaporator installed in the heater does not function, it is only works a place holder and to reduce noise. If there are odors in the evaporator, it can be cleaned in the same way as an A/C system.
Preliminary work
-- Check by switching from fresh air to recirculating air mode to see whether the odor is actually originating from the front heater and A/C unit evaporator.
- The odor can only be fixed by cleaning with the ultrasonic HVAC cleaning system if it originates in the evaporator.
-- Check the plenum chamber and the plenum chamber water drain and clean them if necessary. Refer to PLENUM CHAMBER WATER DRAIN, CHECKING .
-- Remove the dust and pollen filter and check for odors and dirt. Refer to DUST AND POLLEN FILTER, REMOVING AND INSTALLING .
-- Clean the installation slot of the front heater and A/C unit dust and pollen filter (remove leaves, dust and other contaminants). Refer to DUST AND POLLEN FILTER, REMOVING AND INSTALLING .
- On this vehicle, the dust and pollen filter is installed before the Fresh Air Blower -V2-, therefore it must not be removed when cleaning the evaporator.
-- Reseal the dust and pollen filter cover on the heater and A/C unit.
-- Start the engine.
-- Set the A/C system to "recirculating air mode" and switch off the A/C compressor (the indicator lamp in the A/C or A/C MAX button do not turn on).
-- Open the instrument panel vents and, if equipped, the vents in the rear center console.
-- Close the windows and sunroof.
-- Set the lowest possible temperature "cold" temperature setting) for all zones of the A/C system.
-- Adjust to the lowest fresh air blower setting on the Front A/C Display Control Head -E87- and select the airflow direction on the "instrument panel vent" (the vent in the rear center console).
-- On the Front A/C Display Control Head -E87-, select the air flow direction to the "instrument panel vents".
Cleaning
-- Fill the ultrasound A/C cleaner with the Ultrasound A/C Cleaner - Airco-Clean Fluid :VAS6189/1 (note the operating manual).
-- Place the ultrasound A/C cleaner (for example, the Ultrasound A/C Cleaner :VAS6189A ) in the front passenger footwell.
-- Start the ultrasound A/C cleaner (for example the Ultrasound A/C Cleaner :VAS6189A ) according to the operating instructions and route the outlet hose belonging to it so that vapor escaping via the heater and A/C unit recirculation opening (behind the glove compartment near the right wheel housing) is drawn in by the Fresh Air Blower -V2-.
-- Close the vehicle doors.
- The cleaning process takes about 15 to 20 minutes. It is complete when vapor no longer comes out of outlet hose.
Final Procedures
-- Turn off the ultrasound A/C cleaner (for example the Ultrasound A/C Cleaner :VAS6189A ).
-- Open the vehicle doors and air out the passenger compartment for at least 10 minutes.
-- Remove the ultrasound A/C cleaner (for example the Ultrasound A/C Cleaner :VAS6189B ) from vehicle and clean it according to operating instructions.
-- Switch off the ignition.
-- Install the dust and pollen filter. Refer to DUST AND POLLEN FILTER, REMOVING AND INSTALLING .