LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (1 Of 2) >> 87 Air Conditioning >> Working With A/C Service Station >> Pressures, Checking >> Electrically-Driven A/C Compressor, Checking Pressure With A/C System Switched On >> Possible Deviation From Specified Value During The Pressure Test (7 Of 11)

Possible Deviation From Specified Value During The Pressure Test (7 Of 11)

Possible Deviation from Specified Value During the Pressure Test
  • The required cooling output is not attained in the heater and A/C unit evaporator (and in the evaporator for battery cooling).
  • The high pressure pipe corresponds to the specified value
  • Low pressure quickly drops to specified value or lower.
Possible causes for the deviation from specified value and their solutions
  • A/C compressor activation or functionality malfunctioning.
  • Constriction or obstruction in refrigerant circuit
-- Check the activation and function of the A/C compressor and service. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function of the A/C system and the battery regulation. If not error can be determined run hand over refrigerant circuit to check for differences in temperature. Refer to Refrigerant Circuit .-- If difference in temperature is found at one component: If the hose or pipe is kinked or constricted, replace this component. Refer to Refrigerant Circuit . If there is a blockage clean the refrigerant circuit (flush with refrigerant R1234yf). Refer to REFRIGERANT CIRCUIT, CLEANING .
  • There is too little refrigerant in the refrigerant circuit.
-- Extract refrigerant from the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING .-- If the extracted refrigerant quantity is significantly less than the specified capacity (more that 100 g (3.5 oz). Refer to Technical Data , and look for leaks and correct. Refer to LEAKS, FINDING .-- If the extracted refrigerant quantity corresponds to the capacity or is only slightly smaller (maximum 100 g (3.5 oz)) check the expansion valve and shut-off valve for function. Refer to Technical Data and Refrigerant Circuit .
  • The expansion valve for the evaporator in the heater and A/C unit is faulty. Refer to Refrigerant Circuit .
  • A refrigerant shut-off valve is faulty (closed). Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function for the A/C system and the battery regulation. Refer to Refrigerant Circuit .
-- If equipped check the function of the installed shut-off valve. Refer to Refrigerant Circuit .-- Replace the expansion valve for the evaporator in the heater and A/C unit. Refer to Refrigerant Circuit .
Final Procedures
-- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to ELECTRICALLY-DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON .