Charge Air Pressure Control Module -GX34-, REMOVING AND INSTALLING: Removing
- Follow the guidelines for clean working conditions. Refer to GUIDELINES FOR CLEAN WORKING CONDITIONS .
-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .
TIP:
The following step is only required, if the bolts must be replaced.
-- Remove the bolts -arrows- and remove the heat shield -1-.
-- Slightly lift the locking spring -3- with a small screwdriver and remove from the ball pin control rod.
-- Disconnect the connector -2-.
-- Remove the bolts -arrows- and the Charge Air Pressure Control Module -GX34-.