Fuel Delivery Unit/Fuel Level Sensor, Removing And Installing, TFSI Vehicles: Removing
-- Observe the safety instructions. Refer to SAFETY PRECAUTIONS .
-- Follow the guidelines for clean working conditions. Refer to GUIDELINES FOR CLEAN WORKING CONDITIONS .
Danger due to escaping fuel.
- To prevent large quantities of fuel from leaking from the fuel delivery unit when removing, the fuel tank may only be a maximum of 1 /4 full.
-- If required, drain the fuel tank. Refer to FUEL TANK, DRAINING .
-- Disconnect the ground cable from the battery terminal. Refer to BATTERY, DISCONNECTING AND CONNECTING .
-- Move the front seats all the way forward into the highest position.
-- Remove the bench seat / single seat. Refer to BENCH SEAT/SINGLE SEAT, REMOVING AND INSTALLING .
-- Remove the bolts -arrows- and remove the sealing flange cover -1-.
-- Disconnect the connectors -1 and 3- on the sealing flange by unlocking the connector safety catch.
-- Market-specific version/equipment version: release the connector safety catch and disconnect the connector -2-.
-- Country/Rest of World equipment version: disconnect the fuel line -1- to the parking heater metering pump at the sealing flange. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, DISCONNECTING .
The fuel system is under pressure.
Risk of injury from fuel spraying out.
- Wear protective eyewear.
- Wear safety gloves.
- Reduce the pressure: place clean cloths around the connection point and carefully open the connection point.
-- Disconnect the fuel line -2- from the sealing flange. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, DISCONNECTING .
Danger due to escaping fuel.
- To prevent large quantities of fuel from leaking from the fuel delivery unit when removing, the fuel tank may only be a maximum of 1 /4 full.
-- Remove the locking ring using the :T10202 .
-- Pull the sealing flange -1- slightly out of the fuel tank opening and remove the seal -2-.
-- Carefully pull the sealing flange with the fuel lines out of the fuel tank opening.
-- Release the connector safety catch and disconnect the connectors from the sealing flange.
- For Fuel Level Sensor 2 -G169-, present depending on the vehicle version
- For Fuel Level Sensor -G-
FWD Vehicles:
-- Reach through the opening in the fuel tank and disconnect the suction jet line -arrow-. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, DISCONNECTING .
AWD Vehicles:
-- Reach through the opening in the fuel tank and disconnect the suction jet line -arrow-. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, DISCONNECTING .
Continuation for All Vehicles:
-- Reach through the opening in the fuel tank, push the catches -2 and 3- one after the other in the direction of the -arrows- and at the same time release the fuel delivery unit -1-.
Risk of fuel leaking out from the filled fuel delivery unit.
- Lay cloths below to catch the leaking fuel.
-- Carefully remove the fuel delivery unit from the fuel tank opening.
For reasons of clarity, the fuel delivery unit is shown without the fuel lines.