Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Body & Frame >> Seats >> Seat Frames >> 72 Seat Frames >> Front Seat Pneumatic System >> Pneumatic System, Checking >> Leak Test Preparation For Driver Lumbar Support Adjustment Pump -V152- / Front Passenger Lumbar Support Adjustment Pump -V153- And Pressure Line

Leak Test Preparation For Driver Lumbar Support Adjustment Pump -V152- / Front Passenger Lumbar Support Adjustment Pump -V153- And Pressure Line

Special tools and workshop equipment required 

NOTE:

When an appropriate entry is made in the event memory, there is a prompt in "Guided Fault Finding"  to perform a leak check. Refer to Vehicle Diagnostic Tester.

Then the preparations for this leak test are described that must be carried out directly in the seat.

Connection diagram with assignment of the pneumatic lines to the air cushions. Refer to CONNECTION DIAGRAM - PNEUMATIC SYSTEM .

Procedure 

GWWA72-11981Courtesy of AUDI OF AMERICA, LLC

In one of the test steps in "Guided Fault Finding"  , there is a prompt to connect the : VAG1397B  to the pneumatic line from the Driver Lumbar Support Adjustment Pump -V152- / Front Passenger Lumbar Support Adjustment Pump -V153-.

-- Disconnect the pneumatic line -1- for the Driver Lumbar Support Adjustment Pump -V152- / Front Passenger Lumbar Support Adjustment Pump -V153- at the following location. Refer to PNEUMATIC LINES, DISCONNECTING AND CONNECTING .

-- Using the hoses and adapter pieces from the : VAS6618A  , connect the : VAG1397B  to the pneumatic line -1- coming from the pump.

GWWA72-11958Courtesy of AUDI OF AMERICA, LLC
NOTE:

To connect, insert the pneumatic lines into the : VAS6618/3  from both sides in direction of -A arrows-.

Fig 1: Attach The Connecting Sleeves
GWWA72-11372Courtesy of AUDI OF AMERICA, LLC

To release, push the release rings in direction of -B arrows- and simultaneously remove pneumatic lines in direction of -C arrows-.

In one of the test steps in "Guided Fault Finding"  , there is a prompt to connect the : VAG1397B  directly to the pump.

GWWA72-11982Courtesy of AUDI OF AMERICA, LLC

-- Disconnect and free up the pneumatic line at the pump. Refer to Removing - Disconnect the pneumatic line -2- on the pump -1- by pressing the release ring in direction of -arrows-. .

-- Disconnect the pneumatic line -2- from the pump -1- at the following location. Refer to PNEUMATIC LINES, DISCONNECTING AND CONNECTING .

-- Using the line and adapter pieces from the : VAS6618A  , connect the : VAG1397B  to the pneumatic line -2- for the pump -1-.

GWWA72-11959Courtesy of AUDI OF AMERICA, LLC

-- Connect the pneumatic lines following the leak test. Refer to PNEUMATIC LINES, DISCONNECTING AND CONNECTING .