LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Engine Mechanical >> Starter >> Charging System (Battery, Starter And Generator) & Cruise Control (1 Of 2) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Protective Housing, Removing And Installing >> PROTECTIVE HOUSING FOR Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4 AND VH2 >> Installing

PROTECTIVE HOUSING FOR Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4 AND VH2: Installing

GWWA27-10718Courtesy of AUDI OF AMERICA, LLC

-- Insert the Battery, 48 V -A6- -4- into the protective housing -3-. Pay attention to the dimension -a- to the housing edge -5-.

-- Tighten the bolts -2- for the retaining bracket -1-.

-- Install the housing cover.

-- Push on the pressure vent tube until it audibly locks. Check the pressure vent tube for secure fit by pulling on it.

Further installation is performed in reverse order of removal, while noting the following:

-- If necessary, adapt the new Battery, 48 V -A6-. Refer to Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4 AND VH2 .