LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning >> 87 Air Conditioning >> Refrigerant Circuit >> Expansion Valve, Removing And Installing >> Refrigerant Lines, Disconnecting From Front Expansion Valve And Reconnecting >> Removing

Refrigerant Lines, Disconnecting From Front Expansion Valve And Reconnecting: Removing

-- Switch off the ignition.

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

-- Remove the plenum chamber cover. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

GWWA87-12100Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Danger or frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the refrigerant line -B- on the pass-through for the refrigerant lines in the plenum chamber. Refer to REFRIGERANT LINES IN PLENUM CHAMBER, REMOVING AND INSTALLING .

-- Remove the nut -A-.

-- Remove both refrigerant lines -B and C- from the front expansion valve -D-.