Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit >> General Description - Refrigerant Circuit Components >> Pressure Relief Valve

Pressure Relief Valve

The pressure relief valve is installed on the A/C compressor or receiver/dryer.

Fig 1: Exploded View Of Pressure Relief Valve With O-Ring / Seal
GWWV87-1456Courtesy of AUDI OF AMERICA, LLC

At a pressure of approximately 38 bar (551 psi) positive pressure, the valve opens and closes again once pressure has dissipated (at approximately 35 bar (508 psi)).

Refrigerant does not escape completely.

NOTE:

Depending on the version, a transparent plastic washer -B- may be installed on the pressure relief valve -A-, which breaks off as soon as the valve is activated.

Fig 2: Identifying Transparent Plastic Disc -B- And Pressure Relief Valve -A-
GWWA87-11386Courtesy of AUDI OF AMERICA, LLC

Depending on the pressure relief valve version -A-, an additional cover -C- can be slid onto the pressure relief valve -A-. If the pressure in the refrigerant circuit does rise above the pressure relief valve -A- opening pressure and the pressure relief valve opens, the refrigerant does not escape in one direction, but rather it is distributed through the openings -D- under the cover -C-.

If it is necessary to replace a pressure relief valve -A- pay attention to the tightening specification when installing (depending on the manufacturer of the A/C compressor and the version). On "Denso", "Sanden" and "Valeo" A/C compressors an O-ring is installed (tightening specification currently 10 Nm on "Denso" and "Zexel- / Valeo" as well as 15 Nm on "Sanden" A/C compressor). On "Delphi" A/C compressor for example a seal is installed (tightening specification is currently 15 Nm).

Replace the seals (seal or O-ring). Refer to the Parts Information.

If the seals (seal or O-ring) that are installed on the pressure relief valve are not available as a replacement part, the removed seals may be used as an exception (check for damage before installing). If the removed seal is damaged or deformed if necessary replace with a commercially available component. Refer to the Parts Information.

After charging the refrigerant circuit check the installed pressure relief valve for leaks for example using an electronic leak detector.