LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit >> General Description - Refrigerant Circuit Components >> Quick-Release Coupling Connections On Refrigerant Circuit >> Service Connection Measurements

Service Connection Measurements

Service Connection Dimensions -B- Refrigerant R134a Service Connection Refrigerant R1234yf Service Connection
High Pressure Side Low Pressure Side High Pressure Side Low Pressure Side
Outer diameter -D1- 16.0 mm 13.0 mm 17.0 mm 14.0 mm
Outer diameter -D2- 14.0 mm 11.0 mm 13.0 mm 12.0 mm
Section -L1- 4.6 mm 6.15 mm 9.0 mm 4.75 mm
Section -L2- 8.16 mm 9.16 mm 12.5 mm 7.2 mm
Valve installation position (not actuated) -C- 6.1 to 7.1 mm 6.1 to 7.1 mm 8.3 to 9.3 mm 8.3 to 9.3 mm

Service Connections with Primary Sealing Valve (Ball Valve)

Allocation in the vehicle. Refer to Refrigerant Circuit .

Connection with High-Pressure Valve

Fig 1: Exploded View Of Connection With High-Pressure Valve
GWWV87-1435Courtesy of AUDI OF AMERICA, LLC
  1. Socket with internal thread (soldered in)
  2. Seal (version and identification: black or colored. Refer to the Parts Information)
  3. Valve with an external thread and groove for the Seal (identification: ball valve)
  4. Closure Cap Seal
  5. Closure Cap
NOTE:

After connecting, install the hand wheel for the service coupling just far enough into the quick-release coupling adapter until the valve is securely opened inside the service connection (pay attention to the pressure gauge, do not put too much pressure on the valve).

For removing and installing the valve -3- when the refrigerant circuit is evacuated, for example, use an adapter from the Refrigerant Sockets :T10364  .

There are different versions of these valves (with internal or external threads). Therefore the tightening specifications can also differ. The valves -3- with an M12 x 1.5 mm external thread have a tightening specification of 9 Nm ±1 Nm.

There are different versions of these valves and their caps. Make sure the valve version and the closure cap allocation are correct. Refer to the Parts Information.

Connection with Low-Pressure Valve

Fig 2: Exploded View Of Connection With Low-Pressure Valve
GWWV87-1434Courtesy of AUDI OF AMERICA, LLC
  1. Socket with an External Thread and Groove for Seal (soldered in)
  2. Seal (version and identification: black or colored. Refer to the Parts Information)
  3. Valve with an internal thread
  4. Closure Cap Seal
  5. Closure Cap
NOTE:

Install the hand wheel for the service coupling just far enough into the quick-release coupling adapter until the valve is securely opened inside the service connection (pay attention to the pressure gauge, do not put too much pressure on the valve).

For removing and installing the valve -3- when the refrigerant circuit is evacuated, for example, use an adapter from the Refrigerant Sockets :T10364  .

There are different versions of these valves (with internal or external threads). Therefore the tightening specifications can also differ. The currently used valves -3- with an M10 x 1.25 mm internal thread have a tightening specification of 9 Nm ± 1 Nm.

There are different versions of these valves and their caps. Make sure the valve version and the closure cap allocation are correct. Refer to the Parts Information.