Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Engine Mechanical >> Starter >> Charging System (Battery, Starter And Generator) & Cruise Control (2 Of 2) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger :VAS5903 >> BATTERY, CHARGING WITH Battery Charger:VAS5903 >> Procedure

BATTERY, CHARGING WITH Battery Charger:VAS5903: Procedure

-- Turn off the ignition and all electrical consumers and remove the ignition key.

-- Connect the :VAS5903  to the power supply. The last selected operation mode is shown on the display. Refer to Battery Charger .

-- Set the battery type with the INFO  button.

Fig 1: Identifying Battery Charger Displays - Standard Charge (Wet Batteries Or AGM Batteries)
GWWN27-10611Courtesy of AUDI OF AMERICA, LLC

The symbol -1- for "standard charge of wet batteries" or the symbol -2- for "standard charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

-- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑  button or ↓  button.

-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

NOTE:

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.

The :VAS5903  recognizes the nominal voltage of the connected Battery -A- (6 V/12 V/24 V) and begins the charging process automatically.

The :VAS5903  begins the "final charging" when the charge level is approximately 80 to 85%. The fourth bar is indicated on the display -1-. The Battery -A- is ready to be used.

Fig 2: Charging Unit Display, Charge Condition Approx. 80 - 85 %
GWWN27-10170Courtesy of AUDI OF AMERICA, LLC

With a charge status of 100%, all bars are indicated on the display -1-.

Fig 3: Charging Unit Display, Charge Condition 100 %
GWWN27-10180Courtesy of AUDI OF AMERICA, LLC
NOTE:

With the battery type "standard charge", parallel operation of electrical consumers during the charging process is possible. The charging time is lengthened by this.

Depending on the battery type, the :VAS5903  switches to maintenance charging after 1 to 7 hours. To reach a 100% charge level, the Battery -A- should remain connected to the :VAS5903  .

Possible malfunctions and how they are handled

  1. Displayed voltage does not match the nominal voltage:

    -- Hold down the ↑  button or ↓  button until the charging process begins.

  2. Displayed battery voltage does not match rated voltage - charging process has already begun:

    -- Press the START/STOP  button two times.

    -- Hold down the ↑  button or ↓  button until the charging process begins again.

  3. The charger does not recognize a Battery -A-, when the battery voltage is less than 2 V:

    The display remains unchanged.

    The selected battery type and Ampere hours (Ah) are displayed.

Battery -A- charging, ending

-- Press the START/STOP  -button.

-- Remove the charging clamps from the battery terminals.

-- Disconnect the :VAS5903  from the power.