Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Engine Mechanical >> Starter >> Charging System (Battery, Starter And Generator) & Cruise Control (2 Of 2) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger :VAS5903 >> REFRESH CHARGING WITH Battery Charger :VAS5903 >> Notes

REFRESH CHARGING WITH Battery Charger :VAS5903: Notes

Special Tools And Workshop Equipment Required 

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

CAUTION:

"Refresh charging" is not permitted for VW vehicles, because voltage surges can damage the on-board electronics.

The Battery -A- must always be disconnected from the vehicle electrical system when using the "Refresh charging" mode.

CAUTION:

Always set the mode that corresponds to the Battery -A- during the charging process. Refer to the :VAS5903  Operating Instructions.

"Refresh Charging" is suitable for wet batteries, which must be filled with distilled water.

Do not use "refresh charging" mode on maintenance-free wet batteries.

"Refresh charging (Refr)" mode is only used on Batteries -A- that are possibly defective (sulfation). The Battery -A- is then charged to the maximum specific gravity of the electrolyte and the plates are reactivated (removal of sulfation layer).

NOTE:

The Battery -A- temperature must be at least 10 °C (50 °F).