Guidelines For Clean Working Conditions
Even a small amount of contamination can cause malfunctions. Therefore, observe the following guidelines for cleanliness when working on the A/C system:
- Immediately seal off any open lines and connections with clean plugs taken from the Engine Bung Set :VAS6122 , for example.
- Place removed parts on a clean surface and cover them with lint-free cloths.
- Carefully cover or seal opened components if repairs are not performed immediately.
- Only install clean parts: remove the replacement parts from their packaging just before installing them. Do not use any parts that have been kept out of packaging (for example, in a toolbox).
- Do not work with compressed air when the system is open.
- Protect any disconnected connectors from dirt and moisture, and only connect them when they are completely dry.