LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (1 Of 2) >> 87 Air Conditioning >> Working With A/C Service Station >> Refrigerant, Filling In Reservoir

Refrigerant, Filling In Reservoir

-- Connect the bottle with fresh refrigerant R1234yf to the service coupling on the low pressure side on the A/C service station. Refer to the A/C service station Owner's Manual.

-- Perform a gas analysis for the refrigerant to be filled (from the bottle) using the A/C service station. Refer to REFRIGERANT GAS ANALYSIS, PERFORMING .

CAUTION:

Risk of explosion due to overfilling the refrigerant vessels.

Refrigerant can expand and the refrigerant vessel can explode due to overfilling.

- Use a refrigerant vessel with safety valve.

- Never exceed the permitted capacity of the refrigerant vessel.

NOTE:

Depending on the version of the A/C service station and the procedures to be performed a specific minimum amount of refrigerant, refrigerant oil and UV-leak detection are in the corresponding reservoir of the A/C service station. Refer to the A/C service station Owner's Manual.