Possible Deviation From Specified Value During The Pressure Test (6 Of 9)
| Possible Deviation from Specified Value during the Pressure Test |
|---|
|
| Possible causes for the deviation from specified value and their solutions |
|
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to MECHANICALLY DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
NOTE:
With this malfunction, evaporator may ice up although the quantity of refrigerant in circuit is OK.
A malfunction on the Evaporator Vent Temperature Sensor -G263- can also cause icing-up of refrigerant circuit. For this concern also pay attention to the Evaporator Vent Temperature Sensor -G263- measured value.
If there is moisture in the circuit, discharge the A/C compressor and replace the desiccant bag/dryer cartridge (or receiver/receiver/dryer). After cleaning (flushing with refrigerant R1234yf) fill the refrigerant circuit with the correct quantity of refrigerant oil. Refer to REFRIGERANT CIRCUIT, CLEANING , Technical Data and Refrigerant Circuit .