Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R134A Servicing) (2 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit Complaints >> Possible Refrigerant Circuit Concerns >> Possible Concerns

Possible Concerns

NOTE:

For all complaints marked *. Refer to PRESSURES, CHECKING  "Checking pressures".

If a malfunction occurs at only one evaporator in vehicles with two evaporators, also check the pressures in the refrigerant circuit.

Observe the test requirements. Refer to TEST REQUIREMENTS .

Vehicles without a High-Voltage System

Vehicles with a High-Voltage System

All Vehicles

From these, the following complaints may also occur:

The A/C Compressor Makes Noises

-- Tighten compressor securing bolts and compressor bracket using a torque wrench.

-- Check the routing of refrigerant lines; they must not touch other components and must not be subject to strain (align if necessary).

Noise (Refrigerant Hammer) Occurring Immediately after Switching on Air Conditioner and/or When Cornering or Braking

-- Discharge, evacuate and charge refrigerant circuit (too much refrigerant in circuit).

NOTE:

Too much refrigerant oil in the circuit could also cause this problem. This could occur if the amount of refrigerant oil was not adjusted when replacing the A/C compressor.

Water Sprays out of Vents (in Dash Panel or Footwell) Although Air Conditioning System is Otherwise Functioning Properly:

-- Check proper routing of condensate drain; it must not be crushed or kinked.

-- Check condensation drain valve, it must not be clogged by wax or underbody sealant and must close properly.

-- Check plenum chamber cover; it must not be damaged and must be properly installed (to stop water running into evaporator).

-- Check the water drains in plenum chamber; they must not be blocked (for example, by leaves).