Crankshaft, Measuring Axial Clearance
WARNING: This page is about a different variant/trim than selected.
Special tools and workshop equipment required
- Dial Indicator Holder: VW387
- Dial Indicator - 0-10mm: VAS6079
Procedure
-- Attach the Dial Indicator - 0-10mm: VAS6079 with the Dial Indicator Holder: VW387 to the cylinder block and place it against the crankshaft counterweight.
-- Press the crankshaft against the dial gauge by hand and set the dial gauge to "0".
-- Press the crankshaft off the dial gauge and read the measurement.
Axial clearance:
- New: 0.070 to 0.231 mm.