Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis (Single Page) >> External Pages >> Different variant/trim >> Section 1 (Cooling System (4-Cylinder Direct Injection 2.0L 4V TFSI Engine (Ea 888EVO4))) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Electric Coolant Pump, Removing And Installing >> After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, AUDI A6/A7 >> Removing

After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, AUDI A6/A7: Removing

WARNING: This page is about a different variant/trim than selected.

-- Remove the engine cover. Refer to ENGINE COVER, REMOVING AND INSTALLING .

Vehicles with a Particulate Filter: 

GWWA19-12885Courtesy of AUDI OF AMERICA, LLC

-- Free up the wiring harness.

-- Lift the clamps -2-, remove and free up the coolant hoses.

-- Disconnect the connector -4- for the Engine Coolant Level Sensor -G32-.

-- Remove the bolt -3-, and push the coolant expansion tank to the side.

Continuation for All Vehicles: 

GWWA10-12323Courtesy of AUDI OF AMERICA, LLC

-- Unlock the catch in direction of -arrow A- and release in direction of -arrow B-, and remove the vacuum hose.

-- Remove the heat shield boot.

GWWA19-12947Courtesy of AUDI OF AMERICA, LLC

-- Release the retainer in direction of -arrow- and remove the After-Run Coolant Pump -V51- upward from the bracket.

-- Disconnect the connector -3-.

-- Place a cloth underneath to catch any escaping coolant.

-- Loosen the hose clamps -2- to clamp off the coolant hoses with the : 3094  and remove them.

-- Remove the After-Run Coolant Pump -V51-.

-- If the pump should be replaced, remove the bolts -1- and remove the bracket.