01 DTC U140A00 Terminal 30 Is Stored In The ECM (GROUP 01, NO. 25-62)
Reference number: GROUP 01, NO. 25-62
Supersedes refnos: (2073867/2), 2073867/1, GROUP 01, NO. 24-23
01 DTC U140A00 TERMINAL 30 IS STORED IN THE ECM
TECHNICAL SERVICE BULLETIN
| AUDI: | 2017-2025 All Audi vehicles |
| GROUP: | 01 - On-Board Diagnostic |
SERVICE INFORMATION
01 25 62 2073867/2 May 28, 2025. Supersedes Technical Service Bulletin Group 01 number 24-23 dated May 20, 2024, for reasons listed below.
| Model(s) | Year | VIN Range | Vehicle-Specific Equipment |
|---|---|---|---|
| All Audi vehicles | 2017 - 2025 | All | Not Applicable |
CONDITION
| Revision | Date | Purpose |
|---|---|---|
| 2 | - | Revised header (Add Model Year) |
| 1 | 05/20/2025 | Initial publication |
Customer states:
- MIL/exhaust emission lamp lights up in the instrument cluster.
Workshop findings:
- DTC U140A00 and symptom codes 17262 (Terminal 30 open circuit) is stored in ECM, -J623- (address word: 0001).
TECHNICAL BACKGROUND 1
There may be an interruption in the terminal 30 voltage supply for the ECM, -J623-. DTCs may no longer be visible during diagnosis session. In such cases it may be necessary to execute the Guided Fault Finding. The DTC should not be cleared without executing the Guided Fault Finding process.
PRODUCTION SOLUTION
Not applicable.
SERVICE
Guide Fault Finding must be performed.
In the event of a customer complaint, please proceed as follows:
DTC U140A00 and symptom codes 17262 (Terminal 30 open circuit) is stored in ECM, J623- (address word: 0001).
- Do not clear the DTC U140A00 and symptom codes 17262 (Terminal 30 open circuit). The test plan connected to U140A00 should be performed through Guide Fault Finding.
WARRANTY
Only use the following service number if Guided Fault Finding does not identify any faults.
| Claim Type: |
|
||
| Service Number: | 2470 | ||
| Damage Code: | 0055 | ||
| Labor Operations: | GFF/Guided Functions | 0150 0010 | See SRT with associated operations |
| GFF/Guided Functions | 0150 0060 | Time stated on the diagnostic protocol | |
| Claim Comment: | As per TSB 2073867/2 | ||
All warranty claims submitted for payment must be in accordance with the Audi Warranty Policies and Procedures Manual . Claims are subject to review or audit by Audi Warranty.
ADDITIONAL INFORMATION
All part and service references provided in this TSB (2073867 ) are subject to change and/or removal. Always check with your Parts Department and/or ETKA for the latest information and parts bulletins. Please check the Repair Manual for fasteners, bolts, nuts, and screws that require replacement during the repair.
©2025 Audi of America, Inc. All rights reserved. The information contained in this document is based on the latest information available at the time of printing and is subject to the copyright and other intellectual property rights of Audi of America, Inc., its affiliated companies, and its licensors. All rights are reserved to make changes at any time without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, nor may these materials be modified or reposted to other sites, without the prior expressed written permission of the publisher.