Possible Deviation From Specified Value During The Pressure Test (4 Of 9)
| Possible Deviation from Specified Value during the Pressure Test |
|---|
|
| Possible causes for the deviation from specified value and their solutions |
|
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to MECHANICALLY DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
With this malfunction, evaporator may ice up although the quantity of refrigerant in circuit is OK.
If the expansion valve is faulty (constantly closed or does not open far enough), the A/C Compressor Regulator Valve -N280- is actuated to maximum output and low pressure drops to value in graph or below (the A/C compressor draws off refrigerant from low-pressure side). As the refrigerant cannot flow via the expansion valve, if the cooling output is not attained, high pressure may also not increase or only increase slightly due to the absence of energy. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding" Function for the A/C system. Refer to Refrigerant Circuit .
If there is too much refrigerant oil in the circuit, the A/C compressor must be emptied and the desiccant bag (the dryer cartridge) or the receiver/receiver/dryer must be replaced. After cleaning (flushing with refrigerant R1234yf) fill the refrigerant circuit with the correct quantity of refrigerant oil. Refer to REFRIGERANT CIRCUIT, CLEANING , APPROVED REFRIGERANT OILS AND REFRIGERANT OIL CAPACITIES and Refrigerant Circuit .
If the specified value when repeating the check is still not reached and on the refrigerant circuit no malfunction can be determined, clean the refrigerant circuit (flush with refrigerant R1234yf). Refer to REFRIGERANT CIRCUIT, CLEANING .