LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> General Servicing >> Air Conditioning >> 87 Air Conditioning >> Refrigerant Circuit >> Expansion Valve, Removing And Installing >> Front Expansion Valve, Removing And Installing >> Removing

Front Expansion Valve, Removing And Installing: Removing

-- Switch off the ignition.

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

-- Remove the plenum chamber cover. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

GWWA87-12100Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Danger or frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Disconnect both the refrigerant lines -B and C- from the front expansion valve -D- and put aside (do not remove). Refer to REFRIGERANT LINES, DISCONNECTING FROM FRONT EXPANSION VALVE AND RECONNECTING .

-- Remove the bolts -A-.

GWWA87-11745Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the expansion valve -B- from the refrigerant lines to the evaporator.