Refrigerant Lines, Disconnecting And Connecting At Condenser: Installing
The installation takes place in reverse order and is identical for both versions and at the same time note the following:
- Coat the O-ring seals lightly with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT SEALS .
- Install the refrigerant lines stress-free.
-- Clean the refrigerant line connections on the condenser and on the refrigerant lines and check for damage.
-- Check the alignment pin (installed in the condenser connection or the refrigerant line, not present in all connections) for damage and correct seating.
-- Check the routing of the refrigerant lines after attachment. They must be inserted in the provided brackets in a tension-free manner and must not come in contact with other components.
-- Evacuate and charge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
-- Start the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .