Coolant Shut-Off Valve -N82-, Removing And Installing: Removing

GWWA87-12128Courtesy of AUDI OF AMERICA, LLC

-- Switch off the ignition.

CAUTION:

The cooling system is under pressure when the engine is warm. There is a risk of scalding from hot steam and coolant.

Scalding the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Reduce the pressure by covering the coolant expansion tank cap with a cloth and carefully opening it.

-- Carefully open the coolant expansion tank cap -A- (do not completely remove).

TIP

-- Remove the plenum chamber cover. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

-- Cover the area under the connections for the coolant hoses -B and C- to the Coolant Shut-Off Valve -N82- -A- in the plenum chamber for example with absorbent paper.

GWWA87-12150Courtesy of AUDI OF AMERICA, LLC

-- Clamp off the coolant hoses -B and C- with Hose Clamps - Up To 25mm :3094  (or commercially available hose pinch-off pliers).

-- Loosen the hose clamps -D- and remove the coolant hoses -B and C-.

-- Disconnect the connector -E-.

-- Remove the nuts -G- and bolts -F-.

-- Remove the shut-off valve -A- with the bracket -D-.

-- If necessary remove the combination nut -J- and bracket -K-.

TIP