Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> A/C Compressor >> Air Conditioning (Refrigerant R134A Servicing) (2 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Refrigerant Circuit, Tracing Leaks Using Electronic Leak Detector (For Example, :VAG1796) >> Perform a Leak Detection Test for a Refrigerant Circuit that is Filled with Refrigerant:

Perform a Leak Detection Test for a Refrigerant Circuit that is Filled with Refrigerant:

-- On vehicles with a high-voltage system, switch off (deactivate) the "auxiliary climate control" function. Refer to the Owner's Manual and Infotainment/MMI Operating Manual.

-- Switch off the ignition.

-- Start up the leak detector in line with relevant operating instructions.

-- Always hold the test probe underneath the suspected leak.

Fig 1: A/C Refrigerant System, Checking For Leaks
GWWV87-1455Courtesy of AUDI OF AMERICA, LLC

Depending on the model, leak detection is indicated by an increase in clicking rate or a warning tone. Refer to operating instructions for leak detector.

NOTE:

Currents of air quickly disperse refrigerant gas. Drafts must therefore be avoided during leak detection.

Refrigerant gas is heavier than air and will escape.