Blower Motors

Condition Code Procedure
Attaching hardware broken A Require repair or replacement of hardware
Attaching hardware missing C Require replacement of hardware
Attaching hardware not functioning A Require repair or replacement of hardware
Connector (Weatherpack type) leaking A Require repair or replacement
Connector broken A Require repair or replacement
Connector melted, affecting performance A Require repair or replacement
NOTE: Determine cause and correct prior to repair or replacement of part.
Connector melted, not affecting performance 2 Suggest repair or replacement
NOTE: Determine cause and correct prior to repair or replacement of part.
Connector missing C Require replacement
Current draw out of specification B Require repair or replacement
Inoperative A Require replacement
NOTE: Check fan motor/controls. Inoperative includes intermittent operation.
Missing C Require replacement
Motor speed insufficient 2 Suggest repair or replacement
Noisy 2 Suggest replacement
Rotation incorrect for application B Require repair or replacement
Terminal broken A Require repair or replacement
Terminal burned, affecting performance A Require repair or replacement
NOTE: Determine cause and correct prior to repair or replacement of part.
Terminal burned, not affecting performance 2 Suggest repair or replacement
Terminal corroded, affecting performance A Require repair or replacement
Terminal corroded, not affecting performance 2 Suggest repair or replacement
Terminal loose, affecting performance B Require repair or replacement
Terminal loose, not affecting performance 1 Suggest repair or replacement
Vibration 1 Suggest replacement
Wire lead conductors exposed B Require repair or replacement
Wire lead corroded A Require repair or replacement
Wire lead open A Require repair or replacement
Wire lead shorted A Require repair or replacement