Heating, Ventilation & Air Conditioning Systems: Condensers
NOTE:
When replacing this component it is suggested to install or replace high and low side inline filters to prevent future component damage (see Code 5).
| Condition | Code | Procedure |
|---|---|---|
| Abrasion damage, affecting structural integrity | A | Require repair or replacement |
| Abrasion damage, not affecting structural integrity | No service suggested or required | |
| Air flow obstruction, affecting performance | A | Require repair or replacement |
| Attaching hardware broken | A | Require repair or replacement of hardware |
| Attaching hardware missing | C | Require replacement of hardware |
| Attaching hardware not functioning | A | Require repair or replacement of hardware |
| Bent, affecting performance | A | Require repair or replacement |
| Bent, not affecting performance | No service suggested or required | |
| Bracket bent, affecting performance | A | Require repair or replacement |
| Bracket bent, not affecting performance | No service suggested or required | |
| Bracket broken, affecting performance | A | Require replacement |
| Bracket broken, not affecting performance | No service suggested or required | |
| Bracket corroded, affecting performance | A | Require repair or replacement |
| Bracket corroded, not affecting performance | 2 | Suggest repair or replacement |
| Bracket cracked, affecting performance | A | Require repair or replacement |
| Bracket cracked, not affecting performance | 1 | Suggest repair or replacement |
| Bracket holes elongated, affecting performance | A | Require repair or replacement |
| Bracket holes elongated, not affecting performance | No service suggested or required | |
| Bracket loose, affecting performance | A | Require repair or replacement |
| Bracket loose, not affecting performance | 1 | Suggest repair or replacement |
| Bracket missing | C | Require replacement |
| Corroded, affecting structural integrity | A | Require replacement |
| Corroded, not affecting structural integrity | No service suggested or required | |
| Fitting type incorrect (such as compression fitting) | B | Require replacement |
| Flange leaking | A | Require repair or replacement |
| Leaking | A | Require repair or replacement |
| Restricted internally | A | Require repair or replacement |
| Threads damaged | A | Require repair or replacement |
| Threads stripped (threads missing) | A | Require replacement |