Flat Connector Systems
If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts. Refer to SECONDARY LOCK .
Flat Connector System with One Retaining Tab
Courtesy of AUDI OF AMERICA, LLC-- Guide the release tool which fits the connector housing into release channel on connector housing.
-- Grasp contact at wire and push it gently into connector housing in direction of -arrow-.
By pushing the contact in the direction of the connector housing, the contact retaining tab is lifted off the housing shoulder and can be released using the release tool.
-- At the same time, push the release tool in the direction of the connector housing and pull the released contact out of the connector housing in direction of -arrow-.
Courtesy of AUDI OF AMERICA, LLC-- After removing the contact, release tool can be pulled out of the connector housing again.
Flat Connector System with Two Retaining Tabs
Courtesy of AUDI OF AMERICA, LLC-- Guide the release tool which fits the connector housing into release channel on connector housing.
-- Grasp contact at wire and push it gently into connector housing until it stops -arrow-.
By pushing the contact in the direction of the connector housing, contact retaining tabs are lifted off the housing shoulder and released using the release tool.
-- At the same time, push the release tool in the direction of the connector housing and pull the released contact out of the connector housing -arrow-.
Courtesy of AUDI OF AMERICA, LLC-- After removing the contact, release tool can be pulled out of the connector housing again.
Asymmetrical
Courtesy of AUDI OF AMERICA, LLC-- Guide the release tool which fits the connector housing into release channel on connector housing.
-- Grasp contact at wire and push it gently into connector housing -arrow-.
By pushing the contact in the direction of the connector housing, contact retaining tabs are lifted off the housing shoulder and released using the release tool.
-- At the same time, push the release tool in the direction of the connector housing and pull the released contact out of the connector housing -arrow-.
-- After removing the contact, release tool can be pulled out of the connector housing again.