Home >> Audi >> 2021 >> A4 Quattro Premium Plus, 2.0L Eng VIN B >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System (Battery, Starter And Generator) & Cruise Control (1 Of 2) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Battery, Disconnecting And Connecting >> Battery -A-, DISCONNECTING AND CONNECTING, 0K4 AND VH0 >> Connecting

Battery -A-, DISCONNECTING AND CONNECTING, 0K4 AND VH0: Connecting

GWWA27-10692Courtesy of AUDI OF AMERICA, LLC

-- Secure the ground wire -4- on the body.

-- Connect the connector -3- on the Auxiliary Battery -A1-.

When the battery is reconnected, the following steps must be performed:

TIP:

After reconnecting the power supply, the ESP warning lamp can only go out after the vehicle has been driven a few meters.

Tightening Specifications