Special Connector Systems
If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts. Refer to SECONDARY LOCK .
Fasten Contacts
-- Guide the release tool which fits the connector housing into release channel on connector housing.
-- Grasp contact at wire and push it gently into connector housing.
By pushing the contact in the direction of the connector housing, contact retaining tabs are lifted off the housing shoulder and released using the release tool.
-- At the same time, push the release tool in the direction of the connector housing and pull the released contact out of the connector housing -arrow-.
-- After removing the contact, release tool can be pulled out of the connector housing again.
GT 150/280 Contacts
Courtesy of AUDI OF AMERICA, LLC-- Guide the release tool which fits the connector housing under retaining tab into connector housing.
-- Push tool into connector housing until it stops -arrow-.
Contact is ejected from the connector housing.
Courtesy of AUDI OF AMERICA, LLC-- After ejecting the contact, release tool can be pulled out of the connector housing again.
Contacts without Retaining Tabs
Courtesy of AUDI OF AMERICA, LLC-- Insert release tool under retaining tab of connector housing.
-- Push release tool through until it stops by gently lifting -arrow-.
Contact is ejected from the connector housing.