Overview - Instrument Panel CROSSMEMBER
- Bolt
- 20 Nm
- The mounting threads and contact surface must be free of paint, coating and corrosion. The threaded connection serves as the ground connection.
- Quantity: 2
- Threaded Pin
- 20 Nm
- Quantity: 2
- Lifter
- Clip in on the crossmember
- Check the lifter adjusting nut for ease of movement
- Turn the adjusting nut all the way downward until the adjuster engages in the transportation safeguard
- Quantity: 2
- Bolt
- 20 Nm
- Quantity: 2
- Plug
- Quantity: 2
- Bolt
- 20 Nm
- Quantity: 2
- Crossmember
- For the instrument panel
- Removing and installing. Refer to INSTRUMENT PANEL CROSSMEMBER, REMOVING AND INSTALLING .
- Bolt
- 20 Nm
- Bolt
- 20 Nm
- Quantity: 3
- Bolt
- 3.6 Nm
- For A/C unit
- Quantity: 5
- Nut
- 20 Nm
- Replace after removing.
- Quantity: 2
Tightening Specification - Ground Wires on Center Tunnel
-- Nut tightening specification -1- . Refer to => Wiring Diagram .