Voltage Regulator, Removing And Installing - HITACHI Generator: Removing
-- Remove the generator. Refer to GENERATOR, REMOVING AND INSTALLING .
-- Remove the nut -2-.
Courtesy of AUDI OF AMERICA, LLC-- Remove the protective cap -3-.
-- Remove the bolts -4-.
-- Remove the cover -1-.
-- Remove the screws -3-.
-- Remove the nuts -2-.
-- Remove the voltage regulator -1-.