Remove control unit bracket
WARNING:
Working on 12 V electrical system.
Risk of short circuits! Risk of fire!
Risk of short circuits! Risk of fire!
- Make sure that there is no charger connected to the jump start terminal in the engine compartment.
- Detach battery ground lead from battery.
- For auxiliary batteries: Detach battery minus cables from all auxiliary batteries.
NOTE:
RISK OF DAMAGE
Damage to battery terminal, the safety battery terminal or the intelligent battery sensor (IBS).
Damaged battery terminals can lead to malfunctions or vehicle electrical system faults.
Detach battery terminal from battery pole by carefully shifting to and fro. Do not pry off using a tool.
Damage to battery terminal, the safety battery terminal or the intelligent battery sensor (IBS).
Damaged battery terminals can lead to malfunctions or vehicle electrical system faults.
Detach battery terminal from battery pole by carefully shifting to and fro. Do not pry off using a tool.
Preliminary work
- Refer to DISCONNECTING ALL BATTERY GROUND LEADS .
- Refer to REMOVING THE ACOUSTIC COVER .
- Refer to REMOVING THE DME CONTROL UNIT .
- Refer to REMOVING THE INTEGRATED POWER SUPPLY MODULE (PDM) .
- Unlock and loosen lock (1).
- Remove the wiring harness (2) and put to one side.
- Unlock and loosen clamp (3).
- Unlock and loosen wiring harness (1).
- Loosen screws (3).
- Remove the control unit bracket (1) from the guide (2).
- Raise the control unit bracket (1).
- Unlock and loosen the clamps (1).
- Remove the wiring harness (2) and put to one side.
- Slide out and remove the control unit bracket (3).