Removing coolant expansion tank of high-temperature coolant circuit
Preliminary work
- Refer to REMOVING THE UNDERBODY PROTECTION OF THE STEERING GEAR AND THRUST FIELD RESPECTIVELY .
- Refer to REMOVING THE COVER ON LEFT AND RIGHT IN THE ENGINE COMPARTMENT AT THE TOP .
- Refer to REMOVE LEFT FRONT-END STRUT .
Follow-up work
- Refer to INSTALL THE LEFT FRONT-END STRUT .
- Refer to INSTALLING THE COVER ON THE LEFT AND RIGHT IN THE ENGINE COMPARTMENT AT THE TOP
- Refer to INSTALLING THE UNDERBODY PROTECTION OF THE STEERING GEAR OR THE FRONT THRUST FIELD .
WARNING:
Hot surfaces.
Risk of burning!
Risk of burning!
- Perform all work only on components that have cooled down.
NOTE:
TECHNICAL INFORMATION
Use commercially available pinch-off tools to pinch off the coolant hoses.
Use commercially available pinch-off tools to pinch off the coolant hoses.
NOTE:
TECHNICAL INFORMATION
Immobilization period-long fill of coolant!
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
Immobilization period-long fill of coolant!
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
NOTE:
TECHNICAL INFORMATION
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
- Thread in clamping pliers (2) and install.
- Unlock and loosen coolant line (1).
- Catch and dispose of leakage coolant.
- Unlock and loosen lock (1).
- Loosen the coolant expansion tank (2) in the direction of the arrow.
- Feed out coolant expansion tank (2) and set it aside.
- Loosen sealing cap (1).
- Draw the coolant off with a conventional pump.
- Unlock and loosen coolant line (1).
- Catch and dispose of leakage coolant.
- Unlock lock (2).
- Remove coolant expansion tank (3) from guide (4).
- Guide the coolant expansion tank (3) out of the rubber mount (5) and lift.
- Thread in clamping pliers (4) and install.
- Unlock and loosen the connector (1) on the coolant level switch.
- Unlock and loosen coolant line (2).
- Catch and dispose of leakage coolant.
- Remove the coolant expansion tank (3) upwards.